Язык сайта: RUS | ENG

Новинки

Компания Avago Technologies представила новые микросхемы ALM-80110 и ALM-80210

 

подробнее >>

Сверхминиатюрные термокомпенсированные кварцевые генераторы

 

подробнее >>

GaN несогласованный транзистор компании RF Micro Devices

 

подробнее >>

Силовой N-канальный МОП-транзистор NTMFS4927N компании ON Semiconductor

 

подробнее >>

Монолитные интегральные схемы СВЧ переключателей компании Hittite Microwave

 

подробнее >>



Все новинки

1300HAZ OpenCLIENT™ Industrial ThinClient Node


Продукция XYCOM: IndustrialPC-OpenClient - 1300HAZ OpenCLIENT™ Industrial ThinClient Node

OpenCLIENT Terminals & Nodes are industrially hardened platforms used for terminal server network applications. OpenCLIENT terminals are designed to support ACP"s ThinManager server software. Several OpenCLIENT models are available based on your screen size and resolution requirements.

pixel FEATURES
Reduced Maintenance Costs

Because all programs are centrally stored in the server, you can simply upgrade to the latest version of software, make any changes needed to the screens (one time, on the server) and every client in the factory is running the latest code with the updated screens.

The OpenCLIENT is a solid, rugged piece of equipment, with no moving parts of any kind, greatly increasing its MTBF. If the device is accidentally destroyed however, the program continues to run on the server and the application data is unaffected. To replace a damaged unit, the operator plugs in a replacement OpenCLIENT and turns it on. Once the client boots, it displays the same screen as the previous client.

OpenCLIENTs can be powered down and back up at any time without the risk of data loss or damage to the disk directory
structure.


Enhanced Security

If an operator powers down a traditional PC while it is running there is a good chance that it will go through a disk checking procedure at startup. At that time it can be halted or restarted to gain control. A malicious operator could insert a boot disk and restart the PC to add his own programs, or worse enter setup mode during the power-up sequence. The OpenCLIENT avoids both of these weaknesses. It has no disk drives and does not go through the traditional PC power-up sequence.


Simplified Fault Tolerance

If a plant using individual Industrial PCs is really concerned with redundancy or fault tolerance, they must invest money to add special features to every PC in their plant. With a thin client system the IT department simply makes the server redundant and all clients linked to that server become redundant as well.


ThinClient Managememt Software

ThinManager™ software is as easy to read as it is to use. Administrators can simply glance at the management screen and see which terminals are online. They can create a new terminal, or replace a damaged terminal. With ThinManager"s "Default" and "AutoCreate" features, any terminal that has not been booted from that server before can be automatically created and logged in using the parameters of the Default terminal. Clients can therefore be replaced and added directly from the floor without visiting the server. Clients at different locations frequently have different functions, requiring different configurations. If an OpenCLIENT must be reconfigured, the system administrator can restart it from the management interface. Since the client"s software is running on the server, this will not affect the operation of any applications that are being displayed on the client.


OpenCLIENT terminals running the same

application may have similar characteristics. In this case, terminals can be grouped together to provide a visually useful method of checking on the status of all of the clients in that group. Terminals added to the group will inherit all of the
group"s settings. Grouping terminals also makes it easy to apply configuration changes to every member of the group.


Special Features for Industrial Applications

OpenCLIENT™ workstations also support industry specific protocols including DeviceNet, Profibus and high-speed serial ports. The ThinManager software will detect the OpenCLIENT"s model number and build a basic set of modules to support its features. Settings are saved in a file on the server so wherever these OpenCLIENT terminals are installed they will always receive the correct software during boot up.


Flat Panel Monitor Connectivity

OpenCLIENT Nodes (1300 and 1401 models) support connectivity to Xycom Flat Panel Monitors creating a complete industrial solution.
pixel ADDITIONAL FEATURES
  • Enabled by ACP ThinManager (ThinManager sold separately)
  • No-integrated display
  • Reprogrammable keypad or analog resistive touchscreen
  • Built-in PCI 10/100 BaseT Ethernet
  • PC/104 expansion - one card on 1300 models
  • NS Geode GX1 300 MHz processors
  • 128 MB DRAM
  • Parallel, RS-232 and RS-485, PS/2 mouse and keyboard, and VGA ports
  • NEMA 4/4X/12 front panel (units with integrated displays)
  • UL listed for hazardous locations: Class I, Division 2, Groups A, B, C, D (1300HAZ only)
  • pixel TECHNICAL SPECIFICATIONS
    Processor: NS Geode GX1 5x86 300 MHz
    System Ram: 128 MB
    Integrated Video Connector Supports:
  • VGA (640 x 480)
  • SVGA (800 x 600)
  • XGA (1024 x 768)
  • SXGA (1280 x 1024)
    Ethernet: Built-in 10/100 BaseT
    Expansion: PC/104 expansion (one card only)
  • pixel SPECIFICATIONS
  • Power Supply: 55 Watt power
  • AC Power: 100-240V AC, autoranging, 50/60 Hz, 0.5 A (maximum), 21 W nominal*
  • DC Power: 18-32V DC, 24V nominal, 0.9 A (maximum), 21 W nominal*

    *Nominal Power is measured for a base configuration only. Any additional expansion and/or devices will increase the input power required.
  • pixel STANDARDS & RATINGS
    UL

    UL 508 Listed
    UL 1604 Listed*


    cUL

    CSA-C22.2, #142 Listed
    CSA-C22.2, #213 Listed*


    * Class I Division 2, Groups A, B, C, D. Temp. Code: T6
    pixel COMPLIANCE
    CE

    EN 55022, Class A
    EN 61000-6-2
    EN 61000-3-2, Class A
    EN 61000-3-3
    IEC 60950-1


    FCC
     
    47 CFR, Part 15 Class A
    pixel DIMENSIONS
    Refer to product datasheet for product dimensions.
    pixel WARRANTY
    The 1300 node carries a one-year warranty on parts & labor. Extended warranties available
    pixel HOW TO ORDER
    1300-HAZ-CLIENT-AC-ACP: OpenCLIENT 1300 Industrial ThinCLIENT Node with 128 MB SDRAM, Class I Div 2 Approvals
    pixel DOCUMENTATION
    OpenClient Industrial Windows® Terminals - ACP Enabled (includes 1300, 1401, 33XX) (hi-res PDF)
    Industrial PC / FP Monitor Products: New Generations of Industrial PC Technology
    1300XXX CE Certification
    UL Auxiliary Devices Certification for US (NKCR.E107636)
    UL Auxiliary Devices Certification for Canada (NKCR7.E107636)
    UL Information Technology Equipment Including Electrical Business Equipment Certification for US (NWGQ.E181675)
    UL Information Technology Equipment Including Electrical Business Equipment Certification - Component for US (NWGQ2.E181675)
    UL Auxiliary Devices for Use in Hazardous Locations Certification for Canada (NOIV7.E180970)
    UL Auxiliary Devices for Use in Hazardous Locations Certification for US (NOIV.E180970)

    Новости

    Компания Silicon Laboratories представила серию Si51x
    в которую входят кварцевые генераторы и кварцевые генераторы
    подробнее >>

    Компания KEMET представила керамические чип-конденсаторы
    предназначенные для монтажа на единую монолитную структуру.
    подробнее >>

    С праздником 23 февраля

     

    подробнее >>

    Генераторы с низкой G-чувствительностью
     для военных и промышленных приложений
    подробнее >>

    Cнижение цен на модели

    драйверов светодиодов AIMTEC

    подробнее >>



    Все новости